System Analyzer Migrating from UIAPlus
Migrating from the preliminary UIAPlus alpha-release package to the official UIA package[edit]
The ti.uiaplus.loggers.stream.LoggerStreamer2 logger that was shipped in the uiaplus package has been merged back into the mainline UIA package as of uia_1_01_01_14. As a result, the uiaplus package will be discontinued.
To migrate applications from uiaplus to uia, edit the application source code and apply the following string replacements in the order shown below:
Replace | with | file type |
ti_uiaplus_loggers_stream | ti_uia_sysbios | .c, .h |
ti/uiaplus/loggers/stream | ti/uia/sysbios | .c, .h |
ti.uiaplus.loggers.stream | ti.uia.sysbios | .cfg |
ti/uiaplus | ti/uia | .c, .h |
ti_uiaplus_ | ti_uia_ | .c, .h |
ti.uiaplus | ti.uia | .cfg |
LoggerStreamer2 | LoggerStreamer | .c, .h, .cfg |
LogSync2 | LogSync | .c, .h, .cfg |
LoggingSetup2 | LoggingSetup | .cfg |
LoggingSetup.logger = |
LoggingSetup.mainLogger = LoggingSetup.loadLogger = (same logger as above) LoggingSetup.sysbiosLogger = (same logger as above) | .cfg |
A quick way to apply these changes to multiple files in your application is to open a file in your application using Notepad++ and then use Search / Find in Files...
The screenshot below shows an example of how to configure the Find in files dialog to replace ti/uiaplus/loggers/stream
with ti/uia/sysbios
in all .h and .c files in folder c:\MyCcsWorkspace\MyApplication: