Overview and application details[edit]

This is a sample application demonstrating how to define the device's scan time interval in case there is no connection. Default interval is 10 minutes. On setting scan interval, an immediate scan is activated. The next scan will be based on the set interval. This sample application shows how to set and define these Scan-Policies for CC3100.

The application:

  • disables the connection policy so that no scan is run in the background
  • enables scan, sets scan cycle to 10 seconds and sets scan policy. This starts the scanning process
  • retrieves the scan results - all 20 entries in one transaction
  • retrieves the scan results - one by one
  • disables the scan policy


NoteNote: This wiki page is only applicable for CC3100-SDK v1.0.0 and upward releases. For documentation on older SDKs' examples, refer corresponding file in <cc3100-sdk-installation-location>\cc3100-sdk\docs\examples\

Usage[edit]

  • Connect the board to a Windows-PC and configure the terminal-program for seeing the logs - [| CC31xx_&_CC32xx_Terminal_Setting_Wiki] has detailed instructions for configuring the terminal-program
  • Build and launch the application
  • The scanning process starts as explained above
  • See the self explanatory logs on the terminal-program's console. On success, below message will be displayed on the terminal
Scan policy logs 1.png

Limitations/Known Issues[edit]

  • Scan in AP mode is not supported.

Links[edit]

{{#invoke: Navbox | navbox }} {{#invoke: Navbox | navbox }}

E2e.jpg {{
  1. switchcategory:MultiCore=
  • For technical support on MultiCore devices, please post your questions in the C6000 MultiCore Forum
  • For questions related to the BIOS MultiCore SDK (MCSDK), please use the BIOS Forum

Please post only comments related to the article CC3100 Scan Policies Application here.

Keystone=
  • For technical support on MultiCore devices, please post your questions in the C6000 MultiCore Forum
  • For questions related to the BIOS MultiCore SDK (MCSDK), please use the BIOS Forum

Please post only comments related to the article CC3100 Scan Policies Application here.

C2000=For technical support on the C2000 please post your questions on The C2000 Forum. Please post only comments about the article CC3100 Scan Policies Application here. DaVinci=For technical support on DaVincoplease post your questions on The DaVinci Forum. Please post only comments about the article CC3100 Scan Policies Application here. MSP430=For technical support on MSP430 please post your questions on The MSP430 Forum. Please post only comments about the article CC3100 Scan Policies Application here. OMAP35x=For technical support on OMAP please post your questions on The OMAP Forum. Please post only comments about the article CC3100 Scan Policies Application here. OMAPL1=For technical support on OMAP please post your questions on The OMAP Forum. Please post only comments about the article CC3100 Scan Policies Application here. MAVRK=For technical support on MAVRK please post your questions on The MAVRK Toolbox Forum. Please post only comments about the article CC3100 Scan Policies Application here. For technical support please post your questions at http://e2e.ti.com. Please post only comments about the article CC3100 Scan Policies Application here.

}}

Hyperlink blue.png Links

Amplifiers & Linear
Audio
Broadband RF/IF & Digital Radio
Clocks & Timers
Data Converters

DLP & MEMS
High-Reliability
Interface
Logic
Power Management

Processors

Switches & Multiplexers
Temperature Sensors & Control ICs
Wireless Connectivity