NOTICE: The Processors Wiki will End-of-Life on January 15, 2021. It is recommended to download any files or other content you may need that are hosted on processors.wiki.ti.com. The site is now set to read only.
AM1810 Frequency Settings For Profibus
Important Note:
This wiki is in maintenance mode and questions on this device architecture is supported on Sitara E2E forum
PROFIBUS Frequency Settings[edit]
AM1810 device can be configured in two ways to enable PROFIBUS. The frequencies must be set up to enable correct oversampling rate to support 12Mbaud/s on the PROFIBUS UART as well as meet the requirements for DDR memory interface. The frequency settings are listed below.
Mode |
ARM Frequency |
UART Frequency |
EMIF Frequency |
Comments |
---|---|---|---|---|
Variable ARM frequency |
375 MHz (variable) |
156 MHz |
156 MHz (fixed) |
EMIF and UART on same PLL |
Variable EMIF frequency |
312 MHz (fixed) |
156 MHz |
156 MHz (variable) |
ARM and UART on same PLL |
In these two modes, the operating frequencies for major peripherals are as listed in following table.
Peripheral |
Maximum Frequency |
---|---|
ARM |
375 MHz |
DDR2 |
156 MHz |
mDDR |
150 MHz |
Power-on Hours for AM1810[edit]
Depending upon the configured frequency, the expectation of power-on hours changes. The Power-on Hours at 105°C and 1.2V are:
ARM Frequency |
POH Rating |
---|---|
375 MHz |
75 K hours |
340 MHz or slower |
100 K hours |
The AM1810 device datasheet lists these power on hours in Table 4-1 in section 4.3.
Additional Help[edit]
Please use E2E forums for any questions on these frequency settings.